OUPUT | DC VOLTAGE | | | | | | |
| RATED CURRENT | | | | | | |
| CURRENT RANGE | | | | | | |
| RATED POWER | | | | | | |
| PF (Typ.) at FullLoad | | | | | | |
| VOLTAGE TOLERANCE Note.3 | ± 4.0 % | | | | | |
| LINE REGULATION | ± 5.0 % | | | | | |
| LOAD REGULATION | ± 5.0 % | | | | | |
| SETUP, RISE TIME Note.6 ( Full Load) | 650mS/220VAC | | | | | |
| HOLD UP TIME (Typ.) Full Load | 32mS/220VAC | | | | | |
INPUT | VOLTAGE RANGE Note.4 | AC180-264V | | | | | |
| FREQUENCY RANGE | 47~63HZ | | | | | |
| EFFICIENCY (Typ.) | 80.00% | 81.00% | 81% | 85% | 85% | 85% |
| AC CURRENT (Typ.) | 0.74A/220VAC | | | | | |
| INRUSH CURRENT(max.) | COLD START:25A/240VAC | | | | | |
| LEAKAGE CURRENT | <0.75MA/240VAC | | | | | |
PROTEC TION | OVER TEMP. | 130℃ The temperature of the IC become 130℃ , the driver stoped until the temperature below 100℃ | | | | | |
| OVER LOAD | 10 ~ 130% of rated output power, protection type: burping mode, automatic recovery after removal of abnormal conditions | | | | | |
| SHORT PROTECT / NO-LOAD | It will be restart automaticly when the error removed | | | | | |
ENVIRONMENT | WORKING TEMP. | -20~+65℃ | | | | | |
| WORKING HUMIDITY | 20~80%RH non-condensing | | | | | |
| STORAGE TEMP. HUMIDITY | -30~+80℃, 10~95%RH | | | | | |
| TEMP. COEFFICIENT | ±0.03%/℃(0~50℃) | | | | | |
| VIBRATION | 10~500HZ,5G 12min/1cycle,period for 72min.each along X,Y,Z axes | | | | | |
SAFETY & EMC | SAFETY STANDARDS | Passed IP67 certification: design reference UL60950-1,TUV EN60950-1 | | | | | |
| WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC | | | | | |
| ISOLATION RESISTANCE | I/P-O/P:100M Ohms/500VDC/25℃/70%RH | | | | | |
| EMC EMISSION | accord with EN55032,EN61000-3-2 Class C(≥60%load);EN61000-3-3 | | | | | |
| EMC IMMUNITY | accord with EN61000-4-2,3,4,5,6,8,11;EN61547,EN55024,A light industrial standard (2KV surge) | | | | | |
OTHERS | MTBF | ≥438.Khrs, MIL-HDBK-217F(25℃) | | | | | |
| DIMENSION | 149*39*30 MM(L*W*H) | | | | | |
| WEIGHT | g/pcs | | | | | |
NOTE | 1. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25 of ambient temperature. | | | | | | |
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | | | | | | |
| 3. Tolerance : includes set up tolerance, line regulation and load regulation. | | | | | | |
| 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. | | | | | | |
| 5. The Power Supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. | | | | | | |
| 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. | | | | | | |
| 7. The unit might not be suitable for lighting applications in USA. For more information, please contact your Topxin sales assitant | | | | | | |
| 8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over. | | | | | | |